AEG Arctis NoFrost Freezer – something blown – not cold, but lights function.

Home Forums Public Support Forums Help And Support Fridge And Freezer Forum AEG Arctis NoFrost Freezer – something blown – not cold, but lights function.

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #100100
    FreGer
    Participant

    Hi – I have a client with an AEG Arctis “No Frost” freezer. Model A72710GNX1. It is in Denmark, and has mistakenly been conected to a 3 Phase 400V supply. The plugs in Denmark have no fuse – so something inside the freezer has blown. The internal light and the control panel still function, but the freezer makes no sound, and does not get cold. Does anyone know which component is most likely to have blown? Looks like the fan is not working, but I don’t want to replace this, only to find there are more problems that make repair uneconomical.

    #479227
    electrofix
    Moderator

    your compressor has an inverter board to be able to run. this board i think maybe inside the compressor terminal cover

    i dont think its available on its own so if its blown it would mean a compressor change

    Dave

    #479228
    FreGer
    Participant

    Thanks Dave. I’ll check that out.