Hoover VTC580NC all lights flashing

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover VTC580NC all lights flashing

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #100127
    ray.t
    Participant

    Hi,

    Called to this dryer today that seems to work perfectly for a few minutes before stopping with all it’s lights flashing. Does anyone have any info on how to work out the error code for this?

    Thanks,
    Ray

    #479346
    electrofix
    Moderator

    have sent you what should be the test routine

    Dave

    #479347
    ray.t
    Participant

    Thanks Dave.

    #479348
    kaibart
    Moderator

    2 possible causes heater or pcb I would guess strong chance it’s heater

    #479349
    electrofix
    Moderator

    kaibart wrote:2 possible causes heater or pcb I would guess strong chance it’s heater

    i was thinking heater but he did say it was working perfectly so was not sure

    Dave

    #479350
    Hollytree_Technical
    Participant

    In my experience I would say that it may well be a sticking heater relay.

    Jem

    #479351
    ray.t
    Participant

    I called back to this one yesterday and ran the diagnostic sequence (thanks again Dave) It came up with an E15 code. E15= heater relay glued contacts, replace the power card.

    #479352
    electrofix
    Moderator

    or solder in a new heater relay

    did you check the heater had continuity as fault codes are not set in stone and sometimes its not what they say

    Dave

    #479353
    ray.t
    Participant

    Heater was working ok, it would heat for the first few minutes before it started flashing.

    #479354
    kaibart
    Moderator

    Ok the if I knew that I definitely would have said heater relay on pcb 🙂

Viewing 10 posts - 1 through 10 (of 10 total)