indesit IWDC6125

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #100251
    rickard
    Participant

    Hi I have this washer dryer IWDC6125 08062505019631 The dryer works fine on the time settings but when you select the sensor dry it will work for about 10 minutes then switch off and all the horizontal lights flash. I have changed the thermister NTC in the element chamber but still doing the same. Any help please. Andy

    #479855
    electrofix
    Moderator

    its the lights that are not flashing we need to know

    the row of lights with the door lock at the bottom

    door lock is light 1 and counts up


    let me know what is on and off

    Dave

    #479856
    rickard
    Participant

    Hi Dave. lights 1,3 and 4 are illuminated counting up. Thanks

    #479857
    electrofix
    Moderator

    thats a binary number 13 for fault 12

    lamp 1 =1
    lamp 2 =2
    lamp3 =4
    lamp 4 =8

    so its 1 + 4+ 8 =13

    Dave

    #479858
    rickard
    Participant

    Thanks Dave. Seeing as I have changed the ntc and made sure there is no blockages I can only assume a faulty PCB. Many thanks for your advise. Andy

    #479859
    electrofix
    Moderator

    have you checked the wire to the ntc ?

    Dave

Viewing 6 posts - 1 through 6 (of 6 total)
  • You must be logged in to reply to this topic.