Bosch Condenser Dryer WTN83200GB/01

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch Condenser Dryer WTN83200GB/01

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #100653
    DWSERV
    Participant

    Going to see this on Wednesday, any pointers for this problem….. The dryer runs and heats on auto dry settings for around 3 – 4 min, the time display changes to 1 min and then the dryer shuts off with three beeps. Time drying settings works fine with no interruptions.

    Thanks in advance

    #481643
    DWSERV
    Participant

    A bit late now but the I thought Its better to post my fix. I cleared the pump chamber of wet lint reassembled the pump and ran it again all appeared to be working fine. 24 hours later call back to the same problem pulled the pump out again and scrubbed it clean with a toothbrush voila sorted.

    #481644
    electrofix
    Moderator

    strange it worked on timed ok
    you would have thought this fault would affect both timed and auto

    Dave

    #481645
    DWSERV
    Participant

    As I recall the customer called back to say it completed one drying cycle on timed then it failed again.

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.