    Just received a part I ordered, a cooling fan control thermostat. Decided to test for continuity before installing and there is no reading. Is this a faulty part or am I mistaken to think there should be.

    #482360
    tubafan
    Participant

    A cooling fan control stat (switch?) will only have continuity when it gets warm, so I’d expect it to be open circuit at room temperature.

    #482361
    electrofix
    Moderator

    tubafan wrote:A cooling fan control stat (switch?) will only have continuity when it gets warm, so I’d expect it to be open circuit at room temperature.

    agree with that one

    if it had a reading the fan would not stop

    Dave