Luxair LA-110-FLT – Motor pulsing and lights flickering

Home Forums Public Support Forums Help And Support Other Appliances Luxair LA-110-FLT – Motor pulsing and lights flickering

Viewing 13 posts - 1 through 13 (of 13 total)
  • Author
    Posts
  • #100855
    Rake
    Participant

    Hi All,

    we have the above hood and on any fan setting the motor – fan pulses low high low high, if I turn the lights on the fan stops and lights flicker. Without the fan on the lights pulse or flicker too.

    any ideas on what this might be and how to fix it ?

    I have a feeling it’s the PCB but not 100{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d}

    thanks in advance

    #482405
    electrofix
    Moderator

    it is the pcb

    if you can remove it and posr pic i may have more ideas

    Dave

    you may have to host pics offsite

    #482406
    Rake
    Participant

    electrofix wrote:it is the pcb

    if you can remove it and posr pic i may have more ideas

    Dave

    you may have to host pics offsite

    Thanks Dave, I don’t even know where it’s located on this model but I’ll try to find it and post pics if I do.

    #482407
    electrofix
    Moderator

    normally somewhere in the chimney

    Dave

    #482408
    Rake
    Participant

    Ok removed chimney and all I can see there is a transformer.

    will the pcb be on the control panel which houses the light and fan switches ?

    #482409
    Rake
    Participant

    [IMG2=JSON]{“data-align”:”none”,”data-size”:”full”,”src”:”https://postimg.cc/yDz1f95g”}[/IMG2]Not sure if this will work –

    https://postimg.cc/yDz1f95g

    #482410
    electrofix
    Moderator

    yes can see it

    open it and see if there is electronics in there. does look a bit small for a main panel but you dont know till you look

    Dave

    #482411
    Rake
    Participant
    #482412
    Rake
    Participant

    Just checked with Luxair – £74 for a replacement ! Bligh me

    #482413
    electrofix
    Moderator

    ok got the measure of that

    there is a large X2 cap poss 1uF ( you need to check. first pic at the bottom)

    get one and change it and there a good chance it will be fine

    Dave

    #482414
    Rake
    Participant

    Thanks Dave, is that the one in position C4 – 1000 micro farad ?

    #482415
    tubafan
    Participant

    The X2 capacitor Dave is referring to is the large grey rectangular one at the bottom of your picture.

    #482416
    electrofix
    Moderator

    tubafan wrote:The X2 capacitor Dave is referring to is the large grey rectangular one at the bottom of your picture.

    correct

    Dave

Viewing 13 posts - 1 through 13 (of 13 total)