Found water left inside, emptied it then put on short wash…. Did quick function test and it filled, washed, heated BUT then on empty it pulse drained 3 times as normal but no long empty
Tried to cancel it but still the same problem….. Tried 3 other times but thats all it does —- Pulse empties 3 times then nothing!!
I’m thinking PCB error but any other ideas welcome
Thanks
Hi mate,
So if its “pulsing three times as normal” I would be checking the drain pump or for a blockage.
Its unlikely to be the PCB if its getting power to the drain pump and its pulsing as normal
boselecta wrote:Hi mate,
So if its “pulsing three times as normal” I would be checking the drain pump or for a blockage.
Its unlikely to be the PCB if its getting power to the drain pump and its pulsing as normal
Well its doing the short pulse empties but NOT the long one that follows the short empty parts….. it just stops with water inside…. even pressing cancel does the same 3 pulses and NOT the long pump out ???