Neff combi m/w – C17MR02NoB/06 blown inverter

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Neff combi m/w – C17MR02NoB/06 blown inverter

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #101709
    twicknix
    Participant

    Just wanted to check with you guys…

    This microwave in question was sparking all over the the place and the inverter blown – burnt smell

    Do I need to replace the inverter board and magnetron same time to make good repair?

    #485749
    kaibart
    Moderator

    I would definitely change both

    #485750
    twicknix
    Participant

    Thank you very much and I shall order the parts…

    #485751
    electrofix
    Moderator

    these are panasonic parts so you can usually use the panasonic ones which are far cheaper

    Dave

    #485752
    twicknix
    Participant

    electrofix wrote: these are panasonic parts so you can usually use the panasonic ones which are far cheaper

    Dave

    Interesting… do you have the cross reference codes for this and compare against Panasonic? I’ve yet to hear from the owner, I think they were freaked out by the cost of new parts. If I come up with the Panasonic equivalent at much lower prices then they may calm down. Thanks in advance

    #485753
    electrofix
    Moderator

    mag seems to be 2m261-m32 which is on aswo for £42 +vat for gen panasonic

    the inverter you need the numbers off it will be something like F606y etc printed on the coil

    has inverter burnt out? have you checked. normally blows internal fuse when they do

    Dave

    #485754
    twicknix
    Participant

    electrofix wrote:mag seems to be 2m261-m32 which is on aswo for £42 +vat for gen panasonic

    the inverter you need the numbers off it will be something like F606y etc printed on the coil

    has inverter burnt out? have you checked. normally blows internal fuse when they do

    Dave

    Internal fuse is ok which is odd?
    Definitely it is the inverter blown as smelt burning and blackening of pcb on the inverter board.
    Strange that ASWO usually offer alternative part and I have selected the Panasonic one but not for the inverter. Will look again and thank you for your help.

Viewing 7 posts - 1 through 7 (of 7 total)