Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Fisher & Paykel F/F (RF540ADUSX4) Constant leak from ice maker.
- This topic has 7 replies, 2 voices, and was last updated 2 years, 11 months ago by
neon_3SP_glow.
-
AuthorPosts
-
April 20, 2023 at 10:37 am #101902
neon_3SP_glow
ParticipantHello!
I dont usually look at F/F’s. But….
Was called to F&P R54OADUSX4 complaint leak from freezer. The leak is coming from the top LHS of the freezer where the ice maker unit is. Only turning off the water supply to the machine will stop the leak.
This is the ice making unit… ICEMAKER &TRAY ASSY | Fisher & Paykel United Kingdom (fisherpaykel.com)
Q) How does the machine know when to let water into the ice maker?
Q) Is it possible for this valve to stick open?
Q) How does the ice maker detach from the freezer ceiling?Any help gladly appreciated.
Cheers.
April 20, 2023 at 10:47 am #486656neon_3SP_glow
ParticipantPresumably there is a flow meter to ensure enough water is entering the ice making trays, but not too much.
If this flow sensor fails, presumably, the machine logic would think no water is entering the ice making trays and leave the valve open?
Here’s a mediator of the machine… 25483-C RF540ADUSX4 FP EU (mtstatic.com)
April 21, 2023 at 9:16 am #486657electrofix
Moderatorneon_3SP_glow wrote:Hello!
I dont usually look at F/F’s. But….
Was called to F&P R54OADUSX4 complaint leak from freezer. The leak is coming from the top LHS of the freezer where the ice maker unit is. Only turning off the water supply to the machine will stop the leak.
This is the ice making unit… ICEMAKER &TRAY ASSY | Fisher & Paykel United Kingdom (fisherpaykel.com)
Q) How does the machine know when to let water into the ice maker?
Q) Is it possible for this valve to stick open?
Q) How does the ice maker detach from the freezer ceiling?Any help gladly appreciated.
Cheers.
when you say turning off the water stopped the leak, is the water dripping in slowly even if machine has no power ? ie duff valve
Dave
April 24, 2023 at 4:35 pm #486658neon_3SP_glow
ParticipantThanks Dave.
Yes, this was my next thought. I’m attending again tomorrow, so will try unplugging and opening up the supply valve again.
And yes, it was a constant stream of water overflowing from the ice making tray mould.
I just wondered what system/logic the machine uses to allow the correct volume of water into the tray.
THanks for the response.
April 24, 2023 at 4:37 pm #486659neon_3SP_glow
Participant* ‘constant stream of water’ as in no restriction, not dripping.
April 24, 2023 at 7:06 pm #486660electrofix
Moderatorneon_3SP_glow wrote:* ‘constant stream of water’ as in no restriction, not dripping.
with power on or off ?
Dave
May 8, 2023 at 7:57 am #486661neon_3SP_glow
ParticipantHello Dave.
Managed to get the customer to turn electric power off and open water supply tap. Water flowed through.
So have ordered the double valve as it must be jammed open.
Will update after fitting, but can’t see how it can be anything else.
Cheers
May 12, 2023 at 9:17 am #486662neon_3SP_glow
ParticipantNew valve cured leak, old one was stuck open.
Ice maker sorted itself out after dispensing a big block of solid ice.
Thanks for your help.
-
AuthorPosts
- You must be logged in to reply to this topic.