June 16, 2023 at 6:59 am #102027
Twoten
ParticipantI am not a refrigeration engineer but if a customer has a problem with a door I will sometimes take a look.
I have a call to a 20 year old Bosch KIV32900GB/01 where the door doesn’t hold closed fully. This fridge uses the set of four smaller hinges rather than the two larger more common types.
I can’t see any obvious fault with the hinges but the seal doesn’t feel very magnetic. The door seal is clean, there’s nothing in the fridge restricting the closure and the door hasn’t dropped.
Are these hinges sprung closed?
Is this more likely to be the hinges, door seal or should I consider replacing both?June 16, 2023 at 8:22 am #487264electrofix
ModeratorI would say hinges are first place to start
I would check each hinge for damage and try taking them off , maybe one at a time, to see if one of them is jamming
Dave
June 16, 2023 at 9:01 am #487265Twoten
Participantelectrofix wrote: I would say hinges are first place to start
I would check each hinge for damage and try taking them off , maybe one at a time, to see if one of them is jamming
Dave
Thanks Dave,
Do you know if these are self-closing (sprung) or if this relies on the seal magnet?June 16, 2023 at 9:30 am #487266electrofix
Moderatorwell judging by the pics on aswo it does look like there may be a spring element to them
what i am guessing is it will probably be just one hinge causing the problem, find and remove and its a temp fix. hinges are showing £54 plus vat on aswo so not cheap
Dave
June 16, 2023 at 6:15 pm #487267kaibart
ModeratorAs this is a built in unit 1st thing I would be checking before you go changing parts is the install especially as its been there so long must have moved and need re fitting
kaiJune 16, 2023 at 6:40 pm #487268Twoten
Participantkaibart wrote:As this is a built-in unit 1st thing I would be checking before you go changing parts is the installation especially as its been there so long must have moved and need refitting
kaiI checked the position and it appears to be well-secured and the top and bottom fixing plates are aligned with the front of the unit.
June 19, 2023 at 4:56 am #487269Kentish
ParticipantIt’s the older style direct mount. It will be the hinges, but replace them as a set.
-
AuthorPosts