Hotpoint Aquarius TCFS83 water pump on all the time

Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Hotpoint Aquarius TCFS83 water pump on all the time

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #102322
    Isleworth98
    Participant

    Pump replaced, float cleared, switch checked, wiring checked – all ok.

    When plugged in and door closed, pump starts and won’t stop even when no cycle selected.

    Runs cycle, heats up, pump pumps – but continues to pump at end of cycle forever. Only switches off when door opened.

    Any ideas as otherwise dryer is well looked after and in great condition. Board replacement looks like £157 so don’t want to fork out if I’m missing something

    #488351
    electrofix
    Moderator

    can see from manuals what energises the pump

    if it was my job I would check the board and trace the wires back to the board to see if the pump is supplied by a relay or a triac and check if that component short circuit

    from what i can see the pump connects to the board on terminals 2 and 4 of connector CN5

    Dave