have an zanussi micro oven
ZKK47901
944066489 03
on microwave ocasionaly cuts out the fan /light and transformer stops but clock stays on counting down no error codes and could start again without touching it replaced main pcb checked overload but that also stops clock strange fault in my 37 years doing this trade this has beet me i have access to tds offline but no help there
any help appriciated
thanks Daren
I have such kind of problem on my own integrated combi uWave AEG after years of using because restriction of magnetron cooling ventilation channel by dust and tripping safety thermostats.
customer has been shutting door and giving it an extra push shut and that has seemed to work not sure if she wants me to revisit waiting for that phone call but all working fine Thanks Dave your advise sent me in right direction