    rocker
    Participant

    I fitted a new set of carbons today. but I am unable to reset the board…tried the usual 6 0clock then spin etc didn’t work..any advice please…Joihn

    #490108
    electrofix
    Moderator

    try this

    from off press and hold start turn knob ONE “not two” clicks left after about 10 seconds an odd display shows, turn off all now seems ok.

    Dave

    #490109
    neilbow
    Participant

    This normally works for me

    1. Turn off the machine (dial to 0)
    2. Open the door
    3. Turn control knob to position 1
    4. Close the door
    5. Turn off the machine
    6. Turn the control knob to the six-o-clock program, which is spin
    7. Press the option down button and keep it pressed (This is the button left of the display)
    8. Turn the control knob one position left to seven-o-clock (empty/pump out program)
    9. Release the option down button
    10. Turn off the machine.

    Regards Neil

    #490110
    electrofix
    Moderator

    neilbow wrote:This normally works for me

    1. Turn off the machine (dial to 0)
    2. Open the door
    3. Turn control knob to position 1
    4. Close the door
    5. Turn off the machine
    6. Turn the control knob to the six-o-clock program, which is spin
    7. Press the option down button and keep it pressed (This is the button left of the display)
    8. Turn the control knob one position left to seven-o-clock (empty/pump out program)
    9. Release the option down button
    10. Turn off the machine.

    Regards Neil

    thats like 2 reset procedures in one

    but if it works foir you thats ok

    Dave

    #490111
    neilbow
    Participant

    Yes I had a Siemens machine that would only reset this way the standard turn to position 6 and turn one click to the right etc etc would not work

    Regards

    Neil

    #490112
    rocker
    Participant

    Thanks Dave and Neil.. John

    #490113
    electrofix
    Moderator

    neilbow wrote:Yes I had a Siemens machine that would only reset this way the standard turn to position 6 and turn one click to the right etc etc would not work

    Regards

    Neil

    its like they have a full time employee paid to dream up odd reset proceedures lol

    Dave

    #490114
    rocker
    Participant

    Up date : Dave your version worked on this model…thanks again..I agree why cant Bosch make a standard reset on all appliances..??

    #490115
    kaibart
    Moderator

    The reason why they do this is that they don’t want independents to fix them especially now rolling out wifi on all product lines, absolute nightmare