Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Beko dryer DTKCE80021W

Viewing 15 posts - 1 through 15 (of 17 total)
  • Author
    Posts
  • #102725
    seanbabtiste
    Participant

    Hi All , Im struggling to find a part and a price for a Mains Filter Suppressor for the above dryer, can any one Help Tia

    #490189
    electrofix
    Moderator

    am struggling with that too

    let me have the complete serial no

    they dont go often what the fault your getting ?

    Dave

    #490190
    seanbabtiste
    Participant

    hi , Tripping the electric , s/n 22-202911-02 or 7182483000 cheers

    #490191
    electrofix
    Moderator

    and have you tried disconnecting the wires after the suppressor to make sure its that

    Dave

    #490192
    electrofix
    Moderator

    suppressor part no should be either

    1883880500
    or
    1883880600

    both should fit but the one ending 500 is the one i would look for

    Dave

    #490193
    seanbabtiste
    Participant

    #490194
    seanbabtiste
    Participant

    not sure where you mean to disconnect, im presuming also that the black box in pic is the supressor? thx

    #490195
    electrofix
    Moderator

    all the black box is is a connector and unless its burnt its not faulty

    suppressor is inside the steel box

    had one the other day and it was the heater causing the problem

    disconnect the white connectors in your pic and try it

    it wont heat but if it doesnt trip it could be the heater. if heater gets wet it will cause same problem

    Dave

    #490196
    electrofix
    Moderator

    unpug the 2 white connectors

    plug it in and if it trip its not the heater

    if it does not trip then the heater is where you look next

    Dave

    #490197
    seanbabtiste
    Participant

    So , it looks like it was a slightly overheated/burnt connector as in the pics (the black box) i still cant see the mains filter though???
    Thanks Dave for the knowledge its appreciated

    #490198
    seanbabtiste
    Participant

    Experts please
    Mmmmm, ok apparently the dryer has a leaky earth? according to the electrician that tested it, so using google one prong on the earth prong of plug and the other on the metal back frame of dryer and meter on Ohms, am i right so far? but which Ohm settiing 2M, 200k, 20k or 200, and which readings should i be getting for good and bad?, i should also point out at my house the dryer could run for a month solid and not trip but at there house it trips in every socket? I should add ive changed the plug for a brand new one, instead of the plastic sealed type
    Tia

    #490199
    electrofix
    Moderator

    one prong on live and neutral the other on the casing

    2M scale minimum

    Dave

    #490200
    seanbabtiste
    Participant

    On the 2M its black prong on live+neutral and red on back casing and reading point.558 hows that good or bad?

    #490201
    electrofix
    Moderator

    should not get anything

    disconnect heater and see if it goes

    Dave

    #490202
    electrofix
    Moderator

    well either will do
    you are testing resitance from live or neutral to earth

    you should not get a significant reading on either

    Dave