Grundig gtn39250gcw

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #102899
    simonb
    Participant

    Hi everyone, this TD refuses to start intermittently, customer thinks removing the plug for an hour helps but probably just their perception, iv replaced NTC k276, noticed connect show another NTC that’s similar listed meaning their could be two on the dryer? but this sensor fitted down the end of a copper pipe on the right hand side of the dryer, that was a first for me, anyway i forward the video the customer has sent to see if anyone can think of anything else?

    Thanks

    Simon

    [video]https://www.youtube.com/shorts/MB1V2EDeZlE[/video]

    #490968
    electrofix
    Moderator

    ok its a Beko unit

    have you checked door switch ?

    can send service manual but need your email

    Dave

    #490969
    simonb
    Participant

    Thanks Dave, iv not! but was going to try that on my return, but anyhow please can you send it to enquiries@abbey-hey-domestics.co.uk would be really appreciated..

    Regards


    Simon

    #490970
    electrofix
    Moderator

    sorted

    Dave

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.