Logik LHP8W22 stopped working

Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Logik LHP8W22 stopped working

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #103002
    Ian66
    Participant

    Hi new here but looking for some help to fix my out of warranty Tumble dryer. Was working all good not used that much but last week went to dry the bedding and it run for about 3 minutes then stopped with flashing drying level lights 1 and 3 flashing on and off at the same time.
    have taken the top off to see if I can see a reset button that others have talked about but can not see anything. Any suggestions other than to bin it and buy a better make with a longer warranty next time.

    #491431
    electrofix
    Moderator

    nfrom what i can see yours is a heat pump dryer so has no reset button

    if its lights LD3 and LD5 its a problem with the sensor on the heat pump

    fault reads ” compressor NTC is disconnected”

    NTC is a thermostat

    Dave

    #491432
    Lh(poopy)
    Participant

    [USER=”4209″]electrofix[/USER] i have the same model and issues as above. I will post a photo of what lights are on when the machine stops. Could you tell me what they potentially mean? I have already looked into replacement NTC I believe there are two in the machine but don’t want to fire the parts cannon just yet.

    heat exchanger has been vacuumed out and all filters are clear. Sometimes it will run for 45 mins then stop, sometimes it’s 15 seconds

    #491433
    Lh(poopy)
    Participant

    Here is the control panel

    #491434
    electrofix
    Moderator

    ntc fault

    Dave

    #491435
    Lh(poopy)
    Participant

    electrofix wrote:ntc fault

    Dave

    thank you for the advice. I will look into the connection for the compressor ntc and potentially change it.
    much appreciated

Viewing 6 posts - 1 through 6 (of 6 total)