Home › Forums › Trade Technical & Spare Parts Forums › Miele combi microwave – H6400BM – no heating action
- This topic has 15 replies, 3 voices, and was last updated 1 year, 5 months ago by
twicknix.
-
AuthorPosts
-
November 1, 2024 at 11:45 am #103056
twicknix
ParticipantThis was an interesting one here, blooming heavy that microwave oven was!
Customer reported that no microwave action happening, it is touch control unit.
Checked capacitor which is all good. Not done the diodes – in hindsight, I should have done but anyhow…
check magnetron, some discolouration and unsure if it is meant to be black inside the probe? Continuity is good on the magnetron,
checked transformer, had me slightly confused – lack of experience on my part. Both high voltage and low voltage reading were low as expected from what I gathered – high voltage was 0.1 ohm on resistance, the low voltage was similar. The red lead to ground was 86 ohms on resistance and I unsure if this should be way higher?
since it’s a Miele, I am apphrensive on ordering a new magnetron which is a lot of money, I needed to be sure.
What could be the issue here?
November 1, 2024 at 2:58 pm #491618electrofix
Moderatorok you dont have to order a miele mag
i use magsells
https://magsells.co.uk/ring them up as online prices are higher as most common mags are under £50 delivered
ok did you check mag to earth ?
did you check for bad contacts on the heater circuit ?
Dave
November 4, 2024 at 7:05 pm #491619twicknix
Participantelectrofix wrote:ok you dont have to order a miele mag
i use magsells
https://magsells.co.uk/ring them up as online prices are higher as most common mags are under £50 delivered
ok did you check mag to earth ?
did you check for bad contacts on the heater circuit ?
Dave
Re: Mag to earth – no I didn’t for the reason being it is hard wired that I wasn’t able to do this in situ. I guess I can revisit and check again to be sure especially with contacts on heaters and earth leakage.
November 4, 2024 at 11:15 pm #491620electrofix
Moderatorok how much do you know about how the sytem works
do you understand the heater and the high voltage circuit and how it operates along with the safety proceedures to be able to work safely ?
Dave
November 5, 2024 at 9:45 am #491621twicknix
Participantelectrofix wrote: ok how much do you know about how the sytem works
do you understand the heater and the high voltage circuit and how it operates along with the safety proceedures to be able to work safely ?
Dave
I can work with the safety procedures to work safely. I am fully aware of it. I am aware of the heating elements on the microwave and didn’t think it is directly related to non working microwave.
So what I have done so far on the microwave, I have tested the internal fuse, capacitor, transformer (though I am confused on the result), magnetron did show signs of overheating due to discolouration. I would have posted the image up here but it would not let me due to the file size being too large.
i do know from AEG combi microwave that power module fails due to bad earth leak on heating elements. I would be surprised to see this on a Miele. I am more than happy to reeducated. Thank you for asking to check.
November 5, 2024 at 10:23 am #491622electrofix
Moderatorok your getting confused i think
a magnetron works on the same principles of the thermionic radio valves from the 50’s etc. There is a heated Cathode which emits electrons and these electrons are attracted to the high voltage anode. To make it work the transformer has 2 windings, A high voltage winding which is about 2500v AC and a low votage winding which is 12volts Ac or so. The low voltage winding connects to the 2 main terminals of the mag. it has a higher current so any bad joints in the wires or connectors will stop the cathode heating and the mag wont work. Have had bad end connectors, burnt out end connectors, bad connection between the wire and connector. If its properly made these connectors should be crimped and then soldered as the wire is single core so crimps can fail
the high voltage winding is different. one end of the winding connects to the metal chassis (earth) the other end of the winding connects to one side of the capacitor. On the the other side of the capacitor a high voltage diode connect to earth. This same connector connects to the filament anode connection of the magnetron. It works like this, An AC supply goes from zero to full +ve voltage then to zero and the full -ve voltage and back to zero 50 times a second on our supply. Starting at zero the voltage climbs and the current flows from the secondary winding through the capacitor and doide and back to the transformer winding via earth. This charges the capacitor. then the voltage changes direction. In this direction the diode blocks the current flow so the voltage which is in the capacitor adds to the transformer output. this doubles the voltage and changes it from AC to DC
see if that makes it clearer or not lol
Dave
November 10, 2024 at 7:42 pm #491623twicknix
ParticipantThank you for taking the time to go through the steps. Good to be refreshed, still I would like numbers on readings on which part on the transformer.
I will contact customer and start again and test everything.
I have contacted Magsells and they have a transformer for me should I require it. All of this rest on numbers…
Matt
November 10, 2024 at 8:36 pm #491624electrofix
Moderatordisconnect mag
you should get very low ohm reading on the 2 terminals both across the wires you removed and the mag thats the heater circuit
hig voltage output lead from the transformer. you should get a reading from there to earth. reading does not matter unless its meg ohms
across the cap you should see the display count down or up but it should not be short
has it got a high voltage fuse ?
if yes and its ok you can rule out shorts on the high voltage side
Dave
November 12, 2024 at 8:00 am #491625baron
Participanttwicknix wrote:Customer reported that no microwave action happening
Do 220V appear on transformer? Can you select other program without microwave function? Does he works?
First of all check in settings that isn’t in “DEMO” inside “Settings – Showroom programme” …set NONovember 12, 2024 at 8:01 am #491626baron
ParticipantI mean 220v on primary widing…
November 12, 2024 at 3:48 pm #491627twicknix
Participantelectrofix wrote: disconnect mag
you should get very low ohm reading on the 2 terminals both across the wires you removed and the mag thats the heater circuit
hig voltage output lead from the transformer. you should get a reading from there to earth. reading does not matter unless its meg ohms
across the cap you should see the display count down or up but it should not be short
has it got a high voltage fuse ?
if yes and its ok you can rule out shorts on the high voltage side
Dave
Thanks Dave, feeling more empowered now… just few more things…
The primary and secondary leads obviously two goes out and two goes in, both wires should have low continuity resistance?
The high voltage output lead from transformer to earth, I presume you meant earth leak test?
The capacitor is easy as I have the device that test it very quickly, it’s good reading.
With having understood, all this to be completely disconnected prior to testing so that I don’t fry myself and the oven.
November 12, 2024 at 3:51 pm #491628twicknix
Participantbaron wrote:
Do 220V appear on transformer? Can you select other program without microwave function? Does he works?
First of all check in settings that isn’t in “DEMO” inside “Settings – Showroom programme” …set NOI am not aware of demo setting, but that is good to be aware of. As far I am aware that the oven works but no action on microwave. Says that you press start, nothing happens. I have a feeling that it is more likely to be either internal fuse or magnetron or relay switches on the board.
November 12, 2024 at 3:51 pm #491629twicknix
ParticipantOh, will double check the diodes with the battery and multimeter.
November 12, 2024 at 5:14 pm #491630baron
Participanttwicknix wrote:
Says that you press start, nothing happens. I have a feeling that it is more likely to be either internal fuse or magnetron or relay switches on the board.
But, what’s happen with time? did he starts counting down without activating transformer? Do appear sounds of transformer?
Connect a lamp instead transformer and see if he’s lighting… If yes you have on High-voltage part problem if not than PCB(relay) or thermostat or door switches…November 12, 2024 at 8:31 pm #491631electrofix
Moderatorif it does nothing just double check all the door microswitches are activating
Dave
-
AuthorPosts
- You must be logged in to reply to this topic.