Aeg dryer 916098124/03 heater toc

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Aeg dryer 916098124/03 heater toc

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #103156
    mike100
    Participant

    Toc has failed on heater. Part 8581366110329 is expensive. Wondering if possible to get toc from somewhere although it is riveted in.
    Thanks
    Mike

    #491989
    electrofix
    Moderator

    you want get the stat. if you did you have to wonder if its safe and if it went wrong your liable

    cheapest i can see is connect at £69 plus vat

    There is also a tech bulletin to make sure its fitted correctly or it blows TOC

    Dave

    #491990
    mike100
    Participant

    thanks can you give me link to that part. Is that for toc only or a patent heater complete.

    #491991
    electrofix
    Moderator

    complete heater only

    as you said its rivetted so you can never get it off to change it even if you could get one

    part no is correct if you type it into connect search bar

    if you let me have you email can send you the tech bulletin

    Dave

    #491992
    mike100
    Participant

    Thanks Maddox do genuine for about same price so no worries. Just wondered if someone had got round the toc problem as thats all it is . Have fitted new replacements before and they dont last despite all cleaning etc.

    #491993
    electrofix
    Moderator

    thats always a worry when parts are that expensive. The stat is held with steel rivets on a flimbsy back so drilling them out would fail even if you could manage to source a stat. Dont know why they dont use a stat with a reset hole like hotpoint

    the tech bulletin on fitting the element goes into making sure the air flows correctly otherwise the stat blows. they must have had problems otherwise the bulletin would not have been issued

    Dave

Viewing 6 posts - 1 through 6 (of 6 total)