Whirlpool condenser dryer burnt out thermostat

Home Forums Public Support Forums Help And Support Washing Machine Help Forum Whirlpool condenser dryer burnt out thermostat

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #10516
    admin
    Keymaster

    Has anyone else had this problem before, on a Whirlpool or any other make? Our is an AWZ541 condenser dryer.

    I replaced the thermostat pair last night as one of the pair had burnt out and taken the spade connector with it. I think we were lucky it hadn’t caught fire.

    When I restarted the machine to test it, there was an arcing sound and a plume of smoke rose from the rotary switch assembly. On closer inspection I discovered a wire into a spade connector on top of the switch was burnt. I pulled the wire and it came out easily from the connector. The spade connector itself was burnt where the wire had obviously been arcing against it, and the plastic cover was partly melted. I have replaced this too and now all seems to be well.

    The question I have is, are these two failures related? Could the arcing of a bad connection cause arcing on the thermostat which, in turn, caused both to burn out?

    #140412
    Martin
    Participant

    Re: Whirlpool condenser dryer burnt out thermostat

    lewisp wrote:The question I have is, are these two failures related? Could the arcing of a bad connection cause arcing on the thermostat which, in turn, caused both to burn out?

    More than likely I’m afraid and a new Timer Kit replacement is quite costly 🙁

    #140413
    admin
    Keymaster

    Re: Whirlpool condenser dryer burnt out thermostat

    Thanks for the info. I think (hope!) the timer is OK, as the burn-out was on one of the spade connectors on top of the unit as opposed to inside the unit itself. 😕