HOOVER W/DRY A 8610=001 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › HOOVER W/DRY A 8610=001 This topic has 2 replies, 3 voices, and was last updated 20 years, 8 months ago by DAR01. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts July 29, 2005 at 11:27 pm #11006 DAR01Participant No heat when drying. The resetable t/stat had operated. Reset this but still no heat. dryer ele test OK, heat sensing t/stat not showing full short circuit. I assumed t/stat shot, tried again short circiting leads to t/stat, still no heat. Live feed to dryer ele but no neutral, assume problem with control module. The neutral goes direct to the control board. Anyone any ideas? July 30, 2005 at 7:33 am #143580 PhidomParticipant Re: HOOVER W/DRY A 8610=001 If the resetable TOC has tripped it’s usually a fan motor problem. Are you sure there is not another thermal fuse you have overlooked? July 30, 2005 at 6:15 pm #143581 eastlmarkModerator Re: HOOVER W/DRY A 8610=001 check the wires linking the heater/fan unit to the main loom. Often break there. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In