Zanussi E34 WJS1665W

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #11194
    admin
    Keymaster

    Hi,
    I’ve now correctly set the configuration code for this, but it is still not functioning correctly. After a minute or two of operation (in any washing or drying programme) it pauses, and will not start again if you press the Pause button. Checking in the setup reveals E34 as the last fault. Does anyone know what this means?
    Before it stopped running, it had a problem with the drain pump – the impeller fell off, and this has been refitted, and appears to work correctly. Maybe I’ve disturbed something else in removing and fixing this?!?
    Any help would be much appreciated.

    Crispin Murray

    #144318
    admin
    Keymaster

    Re: Zanussi E34 WJS1665W

    I have found out that this to do with the water level / pressure sensors, and the fault has now cleared itself – I suspect it was an airlock from when I had the machine on it’s side.

    #144319
    litlor
    Participant

    Re: Zanussi E34 WJS1665W

    Yes I agree I would be looking at pressure hoses blocked or split usually halfway down the length of the hose

    But power off before you start to look
    ________________

    John

    #144320
    cab
    Participant

    Re: Zanussi E34 WJS1665W

    if this fault apears during drying might be blocked condensor, have had spurious faults caused by down to earth motor 🙄 cab

    #144321
    cobl
    Participant

    Re: Zanussi E34 WJS1665W

    Hi All
    I am having the same reset issue, However it is intermitent. As I live in OZ now and front loaders are not to prelevent can anyone suggest where I might start to look??? (Note not a WM Techo by trade) 😆

Viewing 5 posts - 1 through 5 (of 5 total)