    keldom
    Participant

    hi, my dryer still turns but no heat ,any ideas what is wrong and if so what part i need to replace.thanks

    #144527
    BobHope
    Participant

    Re: white k knight dryer model no cl 767

    Hi,
    look round the back of the appliance there should be a red reset button try pressing that first, if it has tripped check for a blocked filter and condenser.

    hope that helps.

    Bob.

    #144528
    keldom
    Participant

    Re: white k knight dryer model no cl 767

    no it hasnt tripped.

    #144529
    NWAR
    Moderator

    Re: white k knight dryer model no cl 767

    Keldom

    If it’s nor tripped the reset then it’s likely to have blown either the safety stat or the element. Dave Conway should be able to advise you on part numbers and prices.

    As BobHope says check the filter. A blockage can cause the appliance to overheat and blow the thermostat. There’s no point in replacing a part only to have the new one blow due to the original fault remaining.

    Craig

    #144530
    Dave_Conway
    Participant

    Re: white k knight dryer model no cl 767

    There are three thermostats and the heater, any of these can cause this fault:

    Heater 421309221071 – £17.45
    Inlet thermostat – 421309221251 – £19.19
    Exhaust thermostat – 421309221081 – £18.21
    Manual reset thermostat – 421309221261 – £14.17

    All inc VAT, delivery £3.95. You’ll need to either carry out a coninuity check on all of those with the power off :zap: or ask an engineer to diagnose for you, check Repairs@ if you need one 🙂

    Dave.

    #144531
    Dave_Conway
    Participant

    Re: white k knight dryer model no cl 767

    PS, I’ve deleted your other two posts !

    #144532
    NWAR
    Moderator

    Re: white k knight dryer model no cl 767

    There’s a kit which contains the element, inlet stat & reset stat available; part number 421309238041 which retails at £46.80 exc VAT & P&P from MFI. Doesn’t contain the vent stat, though.
    Never seen one of the reset stats go open circuit before.
    If you find that your vent stat has blown check that the vent hose is extracting properly and has no dips along it’s length, such as from leading it under the floor boards. If there is water collecting in your vent hose you have a problem with extraction.

    Craig

    #144533
    Dave_Conway
    Participant

    Re: white k knight dryer model no cl 767

    So there is, first I’ve heard of that kit..

    Keldom, please stop repeadedly posting the same request in other forums, it’s considered as spamming and will be deleted. All the information you need is here 😀

    Regards.

    Dave.

    #144534
    CMDunbar
    Participant

    Re: white k knight dryer model no cl 767

    Hi.

    The pressing of the red reset button worked for me, so thanks for the information.

    Another question however, can anyone tell me where I can download an electronic version of the manual for the White K Knight 767 condenser/tumble dryer?

Viewing 9 posts - 1 through 9 (of 9 total)
  • You must be logged in to reply to this topic.