Re: Indesit WA155 f10: unsure of fault diagnosis
Hi Simon
I’me a bit perplexed – in your first post you said that you had refitted the old p. s/w and it was OK
Did the fault re-occur later?
I have had F10 faults which are track defects on the module which makes the controller think that there is a p.s/w problem when there is’nt. Its just a breakdown in the feedback circuit. But it seems that F10 signifies a complete loss of feedback from the p.s/w. This would happen with a bad contact in the p.s/w for instance (similar to a bad heater relay contact resulting in an F8 ). With the other p.s/w codes F4 & F5 the feedback is still present but it is receiving a different signal than it expects for that part of the program.