Home › Forums › General Trade Forum › Dodgy electrics
- This topic has 8 replies, 5 voices, and was last updated 20 years, 5 months ago by
superfix.
-
AuthorPosts
-
October 20, 2005 at 12:57 pm #12700
superfix
ParticipantJust been to a fully integrated Neff d/w today.
Asked the customer what the problem was, got the usual 30 minute explanation 🙄Anyway to cut a long story short, she coplains the d/w cable is getting hot during use. So I ask her where does it plug in, under the sink she says. Had a look at socket found plug connected to 1mm flex, so I tell her that can’t be the d/w. On further inspection found this single socket connected to the ring main, found this flex with plug attached feeding a double socket at the end of the units. D/W was plugged into this double socket!!!. Then in the other side of the double socket is another plug, which then feeds ANOTHER DOUBLE SOCKET on the worktop with a MICROWAVE and TOASTER plugged into it :eeek:
Best part was she’d had an electrician out first and he said the installation was ok 😕
October 20, 2005 at 1:22 pm #151165mbdas
ParticipantRe: Dodgy electrics
HI
Had one not so long ago, customers ex husband and DIY expert (her kids called him boch it and scarper)customer complained cooker was tripping rcd intermittantly checked cooker insulation was fine and no sign of a short ❓ Turn out he had cut the feed to the cooker and put a 30amp connector on it so he could run there shower on it 😮 I thought it didn’t look right when I realized it was a gas hob.
mark 🙂October 20, 2005 at 1:53 pm #151166Martin
ParticipantRe: Dodgy electrics
boro, please next time take your cellphone with you and take a picture so we can publish in our horror pictures 😆
October 20, 2005 at 3:17 pm #151167NWAR
ModeratorRe: Dodgy electrics
Good call Martin.
We could be doing with a few new pictures to freshen up some of the picture galleries, so send ’em in if you’ve got any good ‘uns.
Unfortunately r600a photos are unlikely to be posted so please don’t anyone go getting their hopes up!
Craig
October 20, 2005 at 3:29 pm #151168Martin
ParticipantRe: Dodgy electrics
NWAR wrote:Unfortunately r600a photos are unlikely to be posted
Ah! That reminds me, I want a word with Bryan 🙄
October 20, 2005 at 3:32 pm #151169admin
KeymasterRe: Dodgy electrics
Moi…
whatever did I do ?
by the way martin…did you enjoy your holiday..
😆
October 20, 2005 at 3:37 pm #151170Martin
ParticipantRe: Dodgy electrics
r600a wrote:by the way martin…did you enjoy your holiday..
Very much so Bryan thanks! Relaxed in the knowledge I was well clear of your camera’s viewfinder for a change :rotfl:
October 20, 2005 at 3:46 pm #151171admin
KeymasterRe: Dodgy electrics
I did have to resist martin’s requests to post the pictures..I tried to explain that the sites members didnt want to see the pictures…
DO THEY ??????
if you do want a copy of the pictures e-mail me at r600a@hotmail.com and i will ensure they arrive in a brown covered e-mail to provide confidentiality.
and of course Martin wont want them again…lol
bryan
October 20, 2005 at 3:53 pm #151172Martin
ParticipantRe: Dodgy electrics
r600a wrote:brown covered e-mail
:rotl:
-