Fisher & Paykel GW608U won’t start cycle

Home Forums Public Support Forums International Forums Australasian Appliance Forum Fisher & Paykel GW608U won’t start cycle

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #13257
    jackwest
    Participant

    Machine wont start to fill with water.

    In diagnostic mode with Spin Speed Hold & Slow LEDS lit I get error code 0000 1011.

    Also in diagnostic mode using Wash Temp Up & Down, hot & cold solenoids activate and water enters the bowl but only for a second. Also using Regular button drain pump works for only a second or two, is this normal for diagnostic mode?

    jackwest193@yahoo.com.au

    #153826
    Penguin45
    Participant

    Re: Fisher & Paykel GW608U won’t start cycle

    Bit of an odd one this – your code suggests a pressure sensor fault. With the tub empty, disconnect air hose to level switch and blow through to ensure that it is clear. If the fault does not clear, the fault probably lies on the motor control board.

    It is unclear from the tech manuals how long the valves and pump should run for in the diagnostic mode.

    Power off if removing panels or covers.

    Regards,
    Penguin45.

    #153827
    jackwest
    Participant

    Re: Fisher & Paykel GW608U won’t start cycle

    Thanks for the quick reply Penguin45.

    I could blow air through the clear plastic tube attached to the motor control board, it seems to be clear, it’s hard to tell being such a small diameter tube and not knowing what’s on the other end of it.

    When I went back into diagnostic mode the water solenoids and drain pump are now operating normally, ie not just for 1-2 secs, but the cycle still doesn’t start. I’m hoping this isn’t getting to odd for you.

    Below is a complete readout in diagnostic mode, just in case it can give some clues.

    0000 – 0000 0000
    0001 – 0000 0000
    0010 – 0000 0000
    0011 – 0000 1011

    0100 – 0100 0010
    0101 – 0000 0111
    0110 – 0000 1101
    0111 – 0000 0001

    1000 – 0001 0011
    1001 – 0000 0111
    1010 – 0000 1101
    1011 – 1111 1111

    1100 – 0000 0001* (*flashing)
    1101 – 0010 0100
    1110 – 0100 0110
    1111 – 0001 0100

    Appreciate for your help so far,
    Jack

    #153828

    Re: Fisher & Paykel GW608U won’t start cycle

    I would agree with my tuxedoed friend, price a new motor controller and find out if they will take it back if it doesn’t fix the problem. 8)

    #153829
    FastAndPro
    Participant

    Re: Fisher & Paykel GW608U won’t start cycle

    On the blue green yellow and grey modules the water valves stay on as long as you keep the buttons pressed pump you switch on and off with one press
    Allways check the resistance of pump motor and inlet valves before replaceing the Motor module double check resistance 16 ohm on the cold inlet valve and look for any rust on solinoid
    Check also for any water leaks from the bearings
    This one does sound like a module BUT ONLY if code comes up with the presure tube disconected and 10 sec after you turn it on 99.9{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d}

Viewing 5 posts - 1 through 5 (of 5 total)