Hotpoint Ultima WM76 – Error Message ‘close door’

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint Ultima WM76 – Error Message ‘close door’

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #13291
    Dales-Electronic
    Moderator

    Just got this one in. Have changed interlock even though it seems old one is OK. Have bypassed interlock neither of which stops the above error message. Module??

    #154057
    bobokines
    Participant

    Re: Hotpoint Ultima WM76 – Error Message ‘close door’

    Usually a blown track on the back of the power board and a blown triac on the control board.

    Bob

    #154058
    Phidom
    Participant

    Re: Hotpoint Ultima WM76 – Error Message ‘close door’

    Is it locking the door? If not, have a look at the tracks on the control pcb as this provides the interlock neutral. The switched live (white) from the interlock goes to the power pcb. If you do need a new control module it needs to be configured to tell it what model it’s in.

Viewing 3 posts - 1 through 3 (of 3 total)