Re: Smeg D/W Fault codes?
Numbering the lights 1-5 from left to right:
If I can assume that it’s 1,2 + 3 on and 5 flashing then the machine is displaying E7 – defective turbine functioning
This alarm is generated when the timer card does not detect the signal comig from the turbine.
This defect can caused by:
– defective turbine
– turbine electric connections wet
– electric connections are not properly connected
– defective electric card
I would suggest attempting to reset the board first, though, as a spike in the supply current could have tripped it. The reset procedure has been posted several times previously; try searching for Smeg AND Reset in the forum search feature