having problems with this machine, when 1st called intermittent faults found ie No drain pump / motor moves but is unable to turn drum. /but sometimes works OK.
fitted refurb module DMPU 9 RS. ran test selected wash prog starts to fill with water but drain pumps is also running, tested pressure switch OK.
can anyone please help..
cheers John
Not sure if this applies here but a couple of times I had Servis machines doing strange things because one inlet valve had gone SHORT circuit ❗
As it was inline with the pump (as a flood prevention mechanism) this led to constant pump out at any fill position.If both valves were energised this could lead to simultaneous fill + pump out.
Mike.
This is quite common. Often due to slight differences in the thickness of the PCB. ALWAYS ALWAYS ALWAYS tighten every pin in each of the 3 edge connectors when changing these modules otherwise these strange faults crop up. I know it sounds illogical that if a pin does NOT make, that the pump should run BUT these modules use a 28 pin microcontroller and 1 pin down often switches unwanted items ON ! Customers often say ‘the edge connectors felt tight’ – well that’s just not good ebough. Tony EMW