December 20, 2005 at 6:36 pm #14193
Colin T
ParticipantCan anyone help with E2 fault code on Bosch KGU3201.
Many thanks
ColinDecember 20, 2005 at 6:42 pm #158527gegsy
ParticipantRe: Bosch F/Freezer fault code
Hi Colin
Freezer compartment sensor failure
GregDecember 20, 2005 at 6:53 pm #158528Colin T
ParticipantRe: Bosch F/Freezer fault code
Thanks Greg, now I know it’s easy to say I thought so, but I know E1 is Fridge sensor but the freezer is the only bit thats working ok, the fridge is not working, no voltage down to solonoid valve, you think freezer sesor would cause that?
Colin
December 20, 2005 at 7:02 pm #158529gegsy
ParticipantRe: Bosch F/Freezer fault code
Hi
I wouldnt have thought so, could be a sticking diverter valve or module problem.Greg
December 20, 2005 at 7:16 pm #158530Colin T
ParticipantRe: Bosch F/Freezer fault code
Thanks again Greg, this customer is someone I know, and back in the summer he said that the fridge was freezing intermitantly, corrected when switched off and defrosted, I said then could be sticking valve and give it a tap when fault on fridge to prove it, and would change if fault could be seen when I was there, not happend since and got call other day with this E2 fault. I’m sure pcb because of no voltage to valve, but could be a valve fault (and sensor?) after that. Christ nows where we should go from here.
Sorry for long post
Thanks againColin
December 20, 2005 at 7:53 pm #158531superfix
ParticipantRe: Bosch F/Freezer fault code
E2 is sensor fault.
Replace pcb to cure fault. New pcb has revamped logic which I believe bypasses faulty sensor.
December 21, 2005 at 8:35 am #158532Colin T
ParticipantRe: Bosch F/Freezer fault code
Thanks to you both, I’ll start with pcb and post results.
Cheers
ColinDecember 21, 2005 at 7:40 pm #158533BSH-MAN
ParticipantRe: Bosch F/Freezer fault code
Colin T wrote:Thanks Greg, now I know it’s easy to say I thought so, but I know E1 is Fridge sensor but the freezer is the only bit thats working ok, the fridge is not working, no voltage down to solonoid valve, you think freezer sesor would cause that?
Colin
Diverter valve is D.C.
😉December 21, 2005 at 10:14 pm #158534Colin T
ParticipantRe: Bosch F/Freezer fault code
Although I have taken a voltage reading on one before I can’t remember what it was but quite high if my memory serves me.
Do you know what voltage should be
Thanks
ColinDecember 21, 2005 at 10:29 pm #158535BSH-MAN
ParticipantRe: Bosch F/Freezer fault code
Colin T wrote:Although I have taken a voltage reading on one before I can’t remember what it was but quite high if my memory serves me.
Do you know what voltage should be
Thanks
ColinAbout 350V D.C. IIRC
There will only be voltage for a short time as the valve is pulsed and the polarity will reverse as the valve is activated. :lesson:
All for future reference, as Boro has your answer.
🙂 -
AuthorPosts