    Penguin45
    Participant

    Pnc 91451680400

    Last error E90, everything then died. Unconfigured board ordered, fitted this am – now all that happens is the rinse light powers up and constant beeping. Will not enter diagnostics, or do anything else really.

    Curiously, refitting the original board will allow a sort of access to diagnostics – holding down the start and skip will eventually lead to the E90 code appearing, but no buttons are functional to enter diagnostics properly.

    No clunking from d/int either – have tried substitution.

    Ideas please?

    Thanks,
    Chris.

    #158730
    Dave_Conway
    Participant

    Re: Zanussi FJDR1466W

    Faulty new PCB is my thought to be honest given that the two faults differ 🙁

    Part number correct ? – 1321571521

    Dave.

    #158731
    farmboy
    Participant

    Re: Zanussi FJDR1466W

    Remove the display board & check the plug connection on it, unplug it & carefully bend the pins back & refit, that usually causes E90/E91.

    #158732
    Tubs
    Participant

    Re: Zanussi FJDR1466W

    Change the interface board Chris, it worked for me, :tup:

    Had similar hair pulling experiance with trying to configure new p.c.b.

    Turned out it had damaged the interface p.c.b when original fault happend.
    You may think that its ok as all the buttons seem to function fine. I changed it as a last resort and hey presto, sorted.