Hotpoint Mistral Plus – 8596P

Home Forums Public Support Forums Help And Support Fridge And Freezer Forum Hotpoint Mistral Plus – 8596P

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #16199
    EwanR
    Participant

    I have taken my Hotpoint Fridge/Freezer over to Spain, where I cannot find any Hotpoint service facilities, and it has recently started playing up. The freezer compartment is operating normally, whereas the fridge is not cooling (seemingly a common problem, looking at other threads). After carrying out basic troubleshooting on it, I have found that the cause of the fault is the circulation fan in the freezer not operating, and thus not cooling the fridge down, though on removing it, it bench-tests correctly. Therefore, the problem appears to be in the fan control circuit. As all parts will have to be purchased from the UK, which part (s) would you advise me to buy first to address this problem?

    Thanks in advance,

    Ewan

    #168774
    Dave_Conway
    Participant

    Re: Hotpoint Mistral Plus – 8596P

    The thermistors are the usual culprits, there’s plenty on them in the other Mistral threads as well 🙂

    You can see them here:

    http://www.ukwhitegoods.co.uk/modules.p … Path=27_71

    If you need either or both, drop me an email rather than ordering from the online shop as it’s UK delivery only carriage but I can arrange delivery to Spain easily enough.

    spares@ukwhitegoods.co.uk

    Dave.

Viewing 2 posts - 1 through 2 (of 2 total)