LIEBHERR KSU4260

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #16683
    tonyclifton
    Blocked

    hi
    got this fridge to look at fault appliance not cooling anything to look for part from obvious
    any help would be great
    tony

    #171021
    agro
    Participant

    Try a line tap i,ve had a couple of lbhr with no gas in

    #171022
    admin
    Keymaster

    Re: LIEBHERR KSU4260

    hi agro

    A BIG warning here..

    DONT use line taps on R600A refrigerant…. It will leak..

    bryan

    #171023
    agro
    Participant

    R600a hi why do they leak i’ve not heard of this no one has told me of it before. Been doing Ref tion for a while . How would you check the system?

    #171024
    admin
    Keymaster

    Re: LIEBHERR KSU4260

    Hi agro

    the make up of r600a is less dense than r134a ect and also works in a vacuum,the vibration will always allow the line tap to leak and as r600a is a butane gas it is flamable.

    bryan

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.