sticking hoover

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #17128
    dopper
    Participant

    got a fairly new hvr hc6130m
    customer puts it on no4 it gets half way into rinses then the timer stops the door lock switches off as if is at the end
    some times will not spin
    wondering if its the timer or the module which is a special
    any ideas
    cheers doppa

    #173087
    Penguin45
    Participant

    Re: sticking hoover

    Timer does weird and wonderful things on these. P/no 91201337, £13 from Masterpart, so cheap enough.

    Chris.

    #173088
    Martin
    Participant

    Re: sticking hoover

    ….also the module is prone to connection problems especially the module plug to the door interlock at the bottom of the board. Always best to take module right off and reconnect having checked all the connector blocks 😉

    #173089
    timdowning
    Participant

    Re: sticking hoover

    Had one the other day which was playing up on the rinses, checked for the normal blockages, low insulation on heater, everything ok, so changed the timer, still no joy, ended being the main module.

    In the future I will still try the timer first as they are cheap and fit a variety of models.

    cheers.

    #173090
    dopper
    Participant

    Re: sticking hoover

    cheers will order a timer

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.