    reported no drain. when set to spin door locks then end light flashes twice pump was burnt out, so replaced it. set to wash door locked filled washed ok then set to drain , end flashed twice no drain
    . I suspect pump has blown board but any info would be helpfull, plus do error code show without going into diagnostic mode never seen one do this before so what are the codes?

    wilf

    #175366
    Turbo
    Participant

    Re: tricity aw1460

    Hi Wilf
    Had the same fault on this model a couple of weeks ago, pump burnt out which blew the board. I noticed that there was no thermal fuse fitted next to the pump windings does anyone know if this would have saved the board from damage?

    #175367
    Penguin45
    Participant

    Re: tricity aw1460

    There is a service update – any twist fit pump should be replaced with 1322082-00/7. No explanation as to why however.

    Chris.

    #175368
    wilf
    Participant

    Re: tricity aw1460

    thats the pump I fitted. think pump number change is just to simplify stock to two types clip and screw, (new pump does have TOC ) looks like a board then! customer will love that! hardly worth doing.

    thanks lads!

    wilf 😉

    #175369
    Penguin45
    Participant

    Re: tricity aw1460

    wilf wrote:hardly worth doing.

    EMW repair these ones.
    Chris.

    #175370
    wilf
    Participant

    Re: tricity aw1460

    have you go an address?

    wilf

    #175371
    Penguin45
    Participant

    Re: tricity aw1460

    http://www.emwelec.co.uk

    Chris.

    #175372
    wilf
    Participant

    Re: tricity aw1460

    thanks
    wilf