WMA31S module track blown.

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #17817
    Simon46
    Participant

    Got a bearing job to do on this model 81147627 but the track is blown on connector X1 pin5.(no drum rotation) Does this mean i need a new motor as well or is it water leakage from rear of tub. Loom rub is not apparent. Meter tests on motor are o.k.

    Regards
    Simon

    #176512
    timdowning
    Participant

    Re: WMA31S module track blown.

    Can you not re-solder / link wire the blown track? Give this a try before you entertain the bearing replacement. If still no drum action and the motor and wiring are ok must be module.

    #176513
    Simon46
    Participant

    Re: WMA31S module track blown.

    Resoldered track testing ok.On to a winner or so i thought. Fitted rear tub, tightening top block bolts and crack.
    Rear LHS bolt has cracked rear blue tub housing. 👿 😥

    S.

    #176514
    timdowning
    Participant

    Re: WMA31S module track blown.

    Why is there always a negative to a positive. Just when you think your getting somewhere. Some jobs are never destined to be completed, (with a profit).