Neff tumble dryer prob r4381 x1 gb/01

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Neff tumble dryer prob r4381 x1 gb/01

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #18044
    den
    Participant

    I thought tumble dryers were simple. Neff doesnt think so.

    I went to a neff r4381x1gb/01. Its got more buttons on it than the space shuttle.
    Anyway, It goes for about two minutes, tumbles and heats. then digital timer goes to 0 and it stops.
    Gives one turn about a minute later.
    Big module on rh side. humidy sensor thing. Ive not got a clue on this one.
    Dont think its connected but cust says its got noisier recently. Fans seem ok and tight, but its rumbly. Anyone any clues.
    Thanks in advance.

    #177504
    BSH-MAN
    Participant

    Re: Neff tumble dryer prob r4381 x1 gb/01

    Are you testing on sensor dry without any load?

    #177505
    Kentish
    Participant

    Re: Neff tumble dryer prob r4381 x1 gb/01

    Agree you need damp clothes for it to keep going. Always a good idea to check the condenser matrix too.

    #177506
    gegsy
    Participant

    Re: Neff tumble dryer prob r4381 x1 gb/01

    Also make sure the paddles have no coating build up from softner usage.

    Greg

    #177507
    superfix
    Participant

    Re: Neff tumble dryer prob r4381 x1 gb/01

    If all the above are ok, check the hose from the pump to the water container for fluff.