siemens gas hob Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › siemens gas hob This topic has 5 replies, 4 voices, and was last updated 19 years, 10 months ago by funkyboogy. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts May 30, 2006 at 6:57 am #18145 funkyboogyParticipant ignition spark stays on after customer has turned on any of the control knobs, does this sound like the ignition unit ?? cheers ally May 30, 2006 at 7:07 am #177881 MartinParticipant Re: siemens gas hob Yes! 🙂 May 30, 2006 at 7:14 am #177882 funkyboogyParticipant Re: siemens gas hob not been to this yet ; its a freind of a freind etc, not over familiar with siemens hobs, but cant think of what else it might be.. ally May 30, 2006 at 10:43 am #177883 Dave_ConwayParticipant Re: siemens gas hob It’s normally the bar that operates the microswitch, it’s common to all the knobs and gets a bit “bent” 😉 Dave. May 30, 2006 at 11:52 am #177884 superfixParticipant Re: siemens gas hob Apply some silicone grease to all the moving parts of the ignition bar, that should sort the problem 😀 . May 30, 2006 at 4:36 pm #177885 funkyboogyParticipant Re: siemens gas hob cheers , i take this bar links all the control valves and tends to get abit sticky ally Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In