Samsung SWF-P1005J error code Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Samsung SWF-P1005J error code This topic has 4 replies, 2 voices, and was last updated 19 years, 9 months ago by PGS. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts June 16, 2006 at 11:45 am #18523 PGSParticipant Hi ive looked in known error codes for above M/C but unable to find E2 anyone any ideas cheers Paul. June 16, 2006 at 12:17 pm #179320 Dave_ConwayParticipant Re: Samsung SWF-P1005J error code Draining (time out) error Paul 🙂 Dave. June 16, 2006 at 12:19 pm #179321 PGSParticipant Re: Samsung SWF-P1005J error code Cheers dave any idea of pump Pt no. Paul. June 16, 2006 at 12:49 pm #179322 Dave_ConwayParticipant Re: Samsung SWF-P1005J error code Standard Askol fits them Paul 😉 Dave. June 19, 2006 at 2:51 pm #179323 PGSParticipant Re: Samsung SWF-P1005J error code Pump fitted today all aok, cheers Dave. Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In