Hotpoint Mistral Plus 8596P fridge warm

Home Forums Public Support Forums Help And Support Fridge And Freezer Forum Hotpoint Mistral Plus 8596P fridge warm

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #18707
    Langmead
    Participant

    My Hotpoint Mistral Plus 8596P fridge freezer (frost free) is showing +24 in the fridge and -22 in the freezer – this seems to be a common problem with this model.

    No ‘E’ faults showing in display but low temp warning for fridge. Door switch ok, condenser and fan working.

    Only thing I could not find working was the internal cooling fan but that bench tested ok.

    Reading your other posts on this problem I replaced the PCB (1/3 of price from QER) – no change.
    Then I replaced the Evaporator Thermistor. This bought life back to the cooling fan in the freezer, comes on at -6 and does go off when the fridge door is opened. It does stay on all the time, even at -22 is this right? The fridge stays the same +24.

    I believe there is a motorised flap in the unit that the cold air from the freezer passes through, if so where it and is it PCB or sensor controlled?

    Other then that, what else can I change that would get this fridge/freezer working again as it fits into our kitchen nicely?

    #180039
    Dave_Conway
    Participant

    Re: Hotpoint Mistral Plus 8596P fridge warm

    Langmead wrote:I believe there is a motorised flap in the unit that the cold air from the freezer passes through, if so where it and is it PCB or sensor controlled?

    It’s in the fridge and PCB controlled (via the fridge thermistor). Check to see if the flap is open, if it is then it’s working OK.

    Dave.

    #180040
    Simon46
    Participant

    Re: Hotpoint Mistral Plus 8596P fridge warm

    Or there is ice in the tube from the freezer to the fridge.

    Regards
    Simon

    #180041
    whitevanman
    Participant

    Re: Hotpoint Mistral Plus 8596P fridge warm

    check that the condensor fan is running and the condensor is not blocked could be linted up.

    Wvm

    #180042
    MKR
    Participant

    Re: Hotpoint Mistral Plus 8596P fridge warm

    After changing the yellow thermistor (evap sensor) did you fully defrost the evaporator and check the ducts were clear?

    If the temperature were -22 freezer and +24 fridge, and the door switch was being switched off fully, I would’ve suspected the yellow thermistor myself.
    Faulty PCB’s and motorized flaps are quite rare and normally result in an error code.