Correct Stat for a Scandinova LF111D?

Home Forums Public Support Forums Spare Parts Help Correct Stat for a Scandinova LF111D?

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #18921
    ChrisK
    Participant

    What do I need to ask for to get the correct stat for a Scandinova LF111D, tall upright larder fridge? It’s a Danfoss type with 3 terminals (3,4 and 6,) plus earth. I’ve already been sent an incorrect stat that I ordered from the model no.

    Apologies, I’ve also posted this in the refrigeration section.

    Any help would be appreciated.

    Chris

    #180891
    Dave_Conway
    Participant

    Re: Correct Stat for a Scandinova LF111D?

    What have you already been sent ?

    These thermostats are pretty universal, the only difference being yours will have an extra long capillary 🙂

    Dave.

    #180892
    ChrisK
    Participant

    Re: Correct Stat for a Scandinova LF111D?

    It’s definately wrong – the one I’ve been sent is the type with only 2 terminals (I presume it for a fridge without a defrost cycle?). The capillary, though not quite as long as the original, was just long enough. Yeah, I know that they are fairly universal – I just can’t remember the specific Danfoss type so that I can go back to the supplier and tell him what I want.

    Cheers, Chris

    #180893
    Dave_Conway
    Participant

    Re: Correct Stat for a Scandinova LF111D?

    Ah, ask for a Ranco VT93 then 😉

    A straight swap for the Danfoss with 3 terminals (plus earth) and a long capillary.

    Dave.

    #180894
    ChrisK
    Participant

    Re: Correct Stat for a Scandinova LF111D?

    Thanks Dave 😀

Viewing 5 posts - 1 through 5 (of 5 total)