AW1560W TRICITY BENBIX W/M Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AW1560W TRICITY BENBIX W/M This topic has 3 replies, 3 voices, and was last updated 19 years, 8 months ago by barryfast. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts August 4, 2006 at 11:49 am #19675 barryfastParticipant Hi this m/c filled up and then went dead opened the door water came out still will not start door s/w ❓ thank’s barryfast August 4, 2006 at 1:45 pm #184032 cabParticipant Re: AW1560W TRICITY BENBIX W/M Hi these machines dont have a pneumatic lock. If water fills above door then machine is switched off the door can be opened after 2 minutes. The most commmon problem is drain pump. If it goes s/c will blow the board. 😳 August 4, 2006 at 4:33 pm #184033 barryfastParticipant Re: AW1560W TRICITY BENBIX W/M thank’s for that will keep you posted Barry August 4, 2006 at 6:19 pm #184034 wilfParticipant Re: AW1560W TRICITY BENBIX W/M new pumps have toc fitted old ones dont Ive hav the old type blow the board. watch out for non gen some still without toc wilf Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In