AW1560W TRICITY BENBIX W/M

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #19675
    barryfast
    Participant

    Hi this m/c filled up and then went dead opened the door water came out
    still will not start door s/w ❓ thank’s barryfast

    #184032
    cab
    Participant

    Re: AW1560W TRICITY BENBIX W/M

    Hi these machines dont have a pneumatic lock. If water fills above door then machine is switched off the door can be opened after 2 minutes. The most commmon problem is drain pump. If it goes s/c will blow the board. 😳

    #184033
    barryfast
    Participant

    Re: AW1560W TRICITY BENBIX W/M

    thank’s for that will keep you posted Barry

    #184034
    wilf
    Participant

    Re: AW1560W TRICITY BENBIX W/M

    new pumps have toc fitted old ones dont Ive hav the old type blow the board. watch out for non gen some still without toc

    wilf

Viewing 4 posts - 1 through 4 (of 4 total)