Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hygena F/F Compressor
- This topic has 9 replies, 5 voices, and was last updated 19 years, 8 months ago by
Kirk.
-
AuthorPosts
-
August 11, 2006 at 8:31 pm #19882
Kirk
ParticipantDoes anyone know what compressor fits in this model
APM6825. S/No 014830428 it is a R600a but eng didn’t take it out to look at the pot.
Thanks Kirk
August 11, 2006 at 10:05 pm #184874Dave_Conway
ParticipantRe: Hygena F/F Compressor
HTP14AH 🙂
Aspera BPE1111Y by the looks of it, check out the price Connect errrm Partmaster want for it :rotl:
Dave.
August 11, 2006 at 11:03 pm #184875Penguin45
ParticipantRe: Hygena F/F Compressor
I think you want to save that one and stick it in “Expensive Spares”…….
What is it really? £40-50?
Chris.
August 12, 2006 at 9:45 am #184876Dave_Conway
ParticipantRe: Hygena F/F Compressor
Penguin45 wrote:What is it really? £40-50?
£37.05 ex VAT, guess where from ? :snigger:
August 12, 2006 at 10:56 am #184877expertcat
Participantthe reason more likly is that the model in question suffers badly from an internal gas leak on fridge evaporater which is not repairable it has also been a problem that if the compressor has died naturally that replacing the compressor aggrivates that the leak will definatly occur so the option is scrap it and dont waste the time and effort and cost I would inmagine that over the last 5 years this model has been around nearly all insured ones will have been replaced due to the extent of the problem.
iceland had this same problem and so did comet all made by ocean/brandt before they went bust.
I been to them and nothing is worse then changing the pot and then 1-2 months later leak happens not so bad if warranty but when its a chargeable call its a ongoing problem with customer.
August 12, 2006 at 11:54 am #184878MKR
ParticipantThe Aspera BPE1111Y is a 1/6hp compressor, too small for this Fridge Freezer… Dave’s quoted HTP14AH which I think is a 1/4hp compressor… I would fit a NBM116Y Aspera compressor to this model. A lot of these ocean fridge freezers had alli pipes lock-ringed to the compressor…. also check for corroded condenser pipes where they touch the low-side pipe.
August 12, 2006 at 3:30 pm #184879expertcat
Participantaccording to aspersa this size of cabinet works ok for 1/6hp compressor and it does
August 12, 2006 at 5:30 pm #184880MKR
ParticipantFair enough, but I would still fit a 1/5hp on this built-in.
August 12, 2006 at 9:03 pm #184881Kirk
ParticipantRe: Hygena F/F Compressor
Thanks for all your input as I have the comps in stock I will have a good look before I start.
Thanks again Kirk
August 13, 2006 at 11:11 am #184882expertcat
Participantsize might be a problem ie dimension of compressor to hole avaialable because it seems aspera are now sending taller compressor out on 1/5hp size.
-
AuthorPosts
- You must be logged in to reply to this topic.