WJD 1257W 1200R ZAN

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #19912
    barryfast
    Participant

    Hi all no heat from dryer clean condencer lot of fluff can any one help
    thank’s Barryfast

    #184996
    Martin
    Participant

    Re: WJD 1257W 1200R ZAN

    Thermal trip gone on overheat stat? Is there power to the heater box? Is the fan running? Is the triple valve coil open circuit?

    #184997
    barryfast
    Participant

    Re: WJD 1257W 1200R ZAN

    Thank’s for that i will keep you posted Barryfast

    #184998
    barryfast
    Participant

    Re: WJD 1257W 1200R ZAN

    hi fan motor not running but currant to stats and heaters etc help Barryfast 💡

    #184999
    Martin
    Participant

    Re: WJD 1257W 1200R ZAN

    barryfast wrote:hi fan motor not running but currant to stats and heaters etc help Barryfast 💡

    No power to the motor then or is the fan unit seized? (Do please bear in mind it is important to check the valve coil to the dryer is OK and that the moment you turn the dryer on, water flows through the condenser!)

    If no power to the fan motor after checking that, then I would have thought you would get error lights flashing at some stage and then have to interrogate the darn module 🙁

    #185000
    barryfast
    Participant

    Re: WJD 1257W 1200R ZAN

    Thank’s martin will give that ago Barry

    #185001
    barryfast
    Participant

    Re: WJD 1257W 1200R ZAN

    Hi yes it was the valve ok up and running barryfast thank’s

Viewing 7 posts - 1 through 7 (of 7 total)
  • You must be logged in to reply to this topic.