    Has any one have the error codes for the hotpoint
    cdt80/85 thanks inadvance . phil

    #187739
    allround
    Participant

    Re: Hotpoint CDT80/85

    F01 Motor triac in short circuit or
    Relay of motor welded
    closed.
    – Verify if moisture has made a short circuit on connector J3;
    – Verify if the motor connectors on board are ok. (Problems of
    aggressive chemicals can generate a short circuit.)
    – Change the board.
    F02 Blocked motor. (Fan
    blocked)
    – Verify if the motor / fan is blocked;
    – Verify the J3 connectors on the board;
    – Replace motor;
    – Replace fan;
    – Replace main board.
    F03 Front NTC open or short
    circuit.
    – Verify efficiency of the J12 connector on the board;
    – Verify NTC on J12 connector, the value at Room temperature
    of the NTC must be around 500 KΩ;
    – If the measurement is out of range verify continuity of wiring
    and verify directly on NTC without wiring;
    – Replace NTC;
    – Replace main board.
    F04 No pump connection.,
    feedback.
    – Verify efficiency of contact J5;
    – Verify wiring J5/Pump;
    – Verify pump;
    – Replace pump;
    – Replace main board.
    F05 No feedback from the pump. – Verify contact efficiency of J5 connector of the board;
    – Verify if tension getting at the pump;
    – Verify pump;
    – Replace pump;
    – Replace main board.
    F06 Non used, active –
    F07 Non used, active –
    F08 Static heater Relay with NA/
    NC contact welded closed
    – Verify efficiency of contact J4;
    – Verify at room temperature on the J4 connector if the
    resistance between Pin 1 and 2 is 48 Ω;
    – Verify continuity between wiring between J4 and Static (lower)
    Heater;
    – Replace Heater;
    – Replace main board.
    F09 Error set up file. EEEPROM
    is not programmed or not
    functioning.
    – If it is a production board with welded EEPROM, replace
    board;
    – If it is a board with removable EEPROM, check the correct
    positioning of the EEPROM.
    F10 Common of heater open,
    one shot open.
    – Verify efficiency of contact J4;
    – Verify at room temperature (20°C) on the J4 connector if the
    resistance between Pin 1 and 2 is 48 Ω;
    – Verify continuity between wiring between J4 and Static (lower)
    Heater;
    – Replace Heater;
    – Replace main board.
    F11 No pump connection. – Verify efficiency of board contact J5;
    – Verify wiring between J5 connector and pump.
    – Replace pump;
    – Replace board.
    F12 No communication between
    display board and control
    board.
    – Verify contact efficiency of board connector J9;
    – Verify continuity between J9 and 5 leads connector of the
    display board;
    – Replace main board;
    – Replace display board.
    F13 Rear NTC open or short
    circuit.
    – Verify efficiency of J4 connector on main board;
    – Verify at room temperature (20°C) is about 500KΩ;
    – Verify continuity of wiring between J4 and NTC rear;
    – If the measurement is out of range verify continuity of wiring
    and verify directly on NTC without wiring;
    – Replace NTC;
    – Replace main board.
    F14 Not used, active –
    F15 Dynamic (PD) heater Relay
    with NA/NC contact welded
    closed.
    – Verify efficiency of contact J4;
    – Verify at room temperature (20°C) on the J4 connector if the
    resistance between Pin 1 and 2 is 48 Ω;
    – Verify continuity between wiring between J4 and Static Heater;
    – Replace Heater;
    – Replace main board.
    F16 Not used, active –
    F17 Master Relay welded closed – Replace main board

    #187740