Re: Whirlpool ADG7540 Tripping Main RCD
Well I managed to get hold of a Megger today and it shows 200Mohm from each terminal of the heating element to earth. That seems to eliminate an earth leak, but could it be that it only fails when hot?
While I had the machine out I think I spotted a very small puncture in the short section of rubber hose that connects to the non-heater element end of the motor/pump assembly. There is also evidence of water collecting on the upperside of the bottom panel (i.e. the panel you have to remove to inspect everything at the bottom of the machine). This may be a red herring as there is no evidence that leaking water has come into contact with any electrical equipment. It also doesn’t fit with fact that the machine is OK on a cold cycle but trips the RCD on a hot cycle.