Bosch GSU34423GB/01 tall freezer frozen solid

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch GSU34423GB/01 tall freezer frozen solid

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #21205
    Simon46
    Participant

    Got this one with frozen solid evaporator. Did this 9 months ago. Defrost ok since. It is in a childrens nursery kitchen so commercial environment. Temp hovering minus 13. Is there a known fault with these appliances? took readings across all the plugs after hairdrying the frost.

    Regards
    Simon.

    #190017
    gegsy
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    I know they don’t (as most frost free) like being sparcely filled as it then makes them work harder.

    Usually very reliable 😀

    Greg

    #190018
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Yeah cust paid 700 quid for it. The job before that i was admiring one thinking that is a nice bit of kit sat next to a old Neff fridge freezer integrated with broken freezer door i was quoting on. Then see two in one day. A weird week so far. still not as weird as the lady with hoover washer dryer seized fan motor was telling me that she had just had a huge central heating flood which sunk next doors garden. The reason. WWII unexploded bomb underground :eeek:

    S.

    #190019
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Frosted again today. Anybody have any ideas on what could play up if a few have been seen by now?

    S.

    #190020
    helo_75
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    are the door seals ok?

    #190021
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Seals ok. Defrost drain was frozen solid as well.

    S.

    #190022
    gegsy
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    In these environments they tend to be in and out of them more than in a domestic environment, also they have been known to leave the door ajar a while until spotted, by then the defrost has no way of recovery.
    Is circulation fan running ok?
    Will send you some info down ok Simon.

    Greg

    #190023
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Ta Greg
    S.

    #190024
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Got another one same fault. Heaters NTC metered ok, put in test mode supply at connecter pins. Seems to point to module. Has anybody come up with a fix for this problem?

    Regards
    Simon

    #190025
    Simon46
    Participant

    Re: Bosch GSU34423GB/01 tall freezer frozen solid

    Well replaced top front PCB 442542.
    Will wait and see.

    S.

Viewing 10 posts - 1 through 10 (of 10 total)