Hotpoint WF860P Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint WF860P This topic has 3 replies, 3 voices, and was last updated 19 years, 6 months ago by johnnyhoz. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts October 5, 2006 at 1:24 pm #21435 johnnyhozParticipant Hi all, have the above machine with a F-01 fault indication which is Short Circuit-Motor Triac. Where is this situated ? and could this fault indicate a fault with the motor? John October 5, 2006 at 3:13 pm #190850 MartinParticipant Re: Hotpoint WF860P johnnyhoz wrote:Where is this situated ? Oh Dear! It’s part of the main board, clearly the motor is at fault as the cause but the board would have to be replaced as well? As it is covered by Hotpoints 5 year parts guarantee, best direct your customer to them to sort it. 😉 October 5, 2006 at 5:16 pm #190851 SDRParticipant Re: Hotpoint WF860P check the motor plug pull on wires as sometimes they break in plug, had this quite often October 7, 2006 at 5:51 am #190852 johnnyhozParticipant Re: Hotpoint WF860P Thanks Martin and SDR John Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In