Re: Samsung RS21NCSV Run Out of Ideas !
That is displayed if defrost is not completed.
Try measuring the continuity of the 2 heaters.
They are wired in parrallel so diconnect one from the other to do so. The heater attached to the evaporator should read circa 400 ohms, the drain channel heater circa 2500 ohms.
We have found several evap heaters at 6000 ohms which has been the fault.
The evap heater is only available by buying the complete evap assembly and then unclipping it….
Kevin