LUX CHEST FREEZER CUTS OUT & LIGHTS FLASH

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries LUX CHEST FREEZER CUTS OUT & LIGHTS FLASH

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #21754
    bzz67
    Participant

    customer has a ecm1957, prod no 920681020.has pcb in handle area.compressor will run for about 15 secs and sounds ok,but then the pcb appears to switch it off and then the lights flash & the alarm sounds.
    any ideas,pcb hopefully.

    #192409
    cab
    Participant

    Re: LUX CHEST FREEZER CUTS OUT & LIGHTS FLASH

    Hi have had loads of trouble with this type of control. might be the board itself, should display a fault. NTC sensor the red LED and the green LED blinking alternately, “-36” in the display, the compressor stops. If it is ntc dont think it can be repaired from memory its foamed into cabinet, but Electrolux have changed suppliers of certain board makes (about3-4 from memory) hope this helps 🙂

    cab

    #192410
    TELL
    Participant

    Re: LUX CHEST FREEZER CUTS OUT & LIGHTS FLASH

    certainly sounds like the pcb, everything goes through it to operate freezer. part no should be 2914068024.
    TELL..