    Hi there!

    I have a F&P Smartdrive 708, I went through the diagnostics procedure (thanks Penguin45) and I get 10000100 (which I think is error # 33?).

    The machines lights come on but nothing happens. I have checked the hot and cold hoses and they are not blocked. The first time it seemed faulty I turned the machine off unplugged it at the wall, and it started back up again. I have probably done that a dozen times since but no love.

    If anybody could put me in the right direction it would be much appreciated.

    Thanking you in advance,
    Warm regards,
    Scott McKean

    #197228
    Penguin45
    Participant

    Re: Fisher & Paykel Smartdrive 708 – 10000100

    33 is 00100001…… Valve failure (solenoid coils), connectors, water not turned on. No failures there means computer problems.

    10000100 is 132, motor problems. This can be wiring loom damage, Rotor Position Sensor failing, short circuit in the stator. Or again, the motor control board.

    Regards,
    Penguin45.